Apparatus & Procedures

test-stand
As shown in Figure 1 above, the test stand consists of a 2 hp motor (left), a torque transducer/encoder (center), a dynamometer (right), and control electronics (not shown). The test bearings support the motor shaft. Single point faults were introduced to the test bearings using electro-discharge machining with fault diameters of 7 mils, 14 mils, 21 mils, 28 mils, and 40 mils (1 mil=0.001 inches). See FAULT SPECIFICATIONS for fault depths. SKF bearings were used for the 7, 14 and 21 mils diameter faults, and NTN equivalent bearings were used for the 28 mil and 40 mil faults. Drive end and fan end bearing specifications, including bearing geometry and defect frequencies are listed in the BEARING SPECIFICATIONS.
Vibration data was collect